Advanced Search
Display options
Filter resources
Text Availability
Article type
Publication date
Species
Language
Sex
Age
Showing 1 to 6 of 6 entries
Sorted by: Best Match Show Resources per page
Cerebral autoregulation assessed by near-infrared spectroscopy: validation using transcranial Doppler in patients with controlled hypertension, cognitive impairment and controls.

European journal of applied physiology

Mol A, Meskers CGM, Sanders ML, Müller M, Maier AB, van Wezel RJA, Claassen JAHR, Elting JWJ.
PMID: 33860383
Eur J Appl Physiol. 2021 Aug;121(8):2165-2176. doi: 10.1007/s00421-021-04681-w. Epub 2021 Apr 16.

PURPOSE: Cerebral autoregulation (CA) aims to attenuate the effects of blood pressure variation on cerebral blood flow. This study assessed the criterion validity of CA derived from near-infrared spectroscopy (NIRS) as an alternative for Transcranial Doppler (TCD).METHODS: Measurements of...

Orthostatic Blood Pressure Recovery Measured Using a Sphygmomanometer Is Not Associated with Physical Performance or Number of Falls in Geriatric Outpatients.

Gerontology

Mol A, Blom MEC, van den Bosch DJ, Van Wezel RJA, Meskers CGM, Maier AB.
PMID: 33902032
Gerontology. 2021 Apr 26;1-5. doi: 10.1159/000515658. Epub 2021 Apr 26.

BACKGROUND: Orthostatic hypotension (OH) and impaired OH recovery derived from beat-to-beat blood pressure (BP) measurements are associated with detrimental clinical outcome, but the clinical relevance of OH recovery assessed using the widely available sphygmomanometer is still unclear.METHOD: 635 geriatric...

Orthostatic Blood Pressure Recovery Measured Using a Sphygmomanometer Is Not Associated with Physical Performance or Number of Falls in Geriatric Outpatients.

Gerontology

Mol A, Blom MEC, van den Bosch DJ, Van Wezel RJA, Meskers CGM, Maier AB.
PMID: 33902032
Gerontology. 2021 Apr 26;1-5. doi: 10.1159/000515658. Epub 2021 Apr 26.

BACKGROUND: Orthostatic hypotension (OH) and impaired OH recovery derived from beat-to-beat blood pressure (BP) measurements are associated with detrimental clinical outcome, but the clinical relevance of OH recovery assessed using the widely available sphygmomanometer is still unclear.METHOD: 635 geriatric...

Multimodal Monitoring of Cardiovascular Responses to Postural Changes.

Frontiers in physiology

Mol A, Maier AB, van Wezel RJA, Meskers CGM.
PMID: 32194438
Front Physiol. 2020 Mar 03;11:168. doi: 10.3389/fphys.2020.00168. eCollection 2020.

BACKGROUND: In the poorly understood relationship between orthostatic hypotension and falls, next to blood pressure (BP), baroreflex sensitivity (BRS) and cerebral autoregulation (CAR) may be key measures. The posture- and movement dependency of orthostatic hypotension requires continuous and unobtrusive...

Severe fever with thrombocytopenia syndrome virus (SFTSV)-host interactome screen identifies viral nucleoprotein-associated host factors as potential antiviral targets.

Computational and structural biotechnology journal

Cao J, Lu G, Wen L, Luo P, Huang Y, Liang R, Tang K, Qin Z, Chan CC, Chik KK, Du J, Yin F, Ye ZW, Chu H, Jin DY, Yuen KY, Chan JF, Yuan S.
PMID: 34712400
Comput Struct Biotechnol J. 2021 Oct 01;19:5568-5577. doi: 10.1016/j.csbj.2021.09.034. eCollection 2021.

Severe fever with thrombocytopenia syndrome virus (SFTSV) is an emerging tick-borne virus that causes severe infection in humans characterized by an acute febrile illness with thrombocytopenia and hemorrhagic complications, and a mortality rate of up to 30%. Understanding on...

Feasibility of Diagnosing Initial Orthostatic Hypotension Using a Continuous Blood Pressure Device in Geriatric Rehabilitation Inpatients: RESORT.

Gerontology

Tran J, Mol A, Iseli RK, Lim WK, Meskers CGM, Maier AB.
PMID: 35038699
Gerontology. 2022 Jan 17;1-10. doi: 10.1159/000521411. Epub 2022 Jan 17.

BACKGROUND: Initial orthostatic hypotension (IOH) is highly prevalent in older adults and may interfere with the ability to regain function after acute hospitalization. IOH assessment requires a non-invasive, beat-to-beat continuous blood pressure device, which is not widely used in...

Showing 1 to 6 of 6 entries