[Analysis on the main difference and impact between IEC 60601-1 in Ed. 3.1 and GB 9706.1-2007].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation

Zheng J, He J, Yu X.
PMID: 25980136
Zhongguo Yi Liao Qi Xie Za Zhi. 2014 Nov;38(6):442-4.

For the preparation of implementing IEC 60601-1 Ed. 3.1 in advance, this paper analyzes the main difference between IEC 60601-1 Ed. 3.1 and GB 9706.1-2007, and discusses the possible influence to medical device designing and testing.

Computer input devices.

Software in healthcare

Tuttle RA.
PMID: 10280580
Softw Healthc. 1986 Apr-May;4(2):50-3.

Although some computer input devices have been in use for decades, claims of new devices are announced almost daily. This overview of historic, current, and future device technologies addresses the issue of what is truly new.

Educating Students About Standardisation Relating to Universal Design.

Studies in health technology and informatics

Darzentas J.
PMID: 27534303
Stud Health Technol Inform. 2016;229:180-8.

Standardisation education is rarely taught to students in the design disciplines in academic settings, and consequently there is not much evidence about best practices. This paper examines this situation, and elaborates on some of the possible reasons for this...

Improved power control using optimal adjustable coefficients for three-phase photovoltaic inverter under unbalanced grid voltage.

TheScientificWorldJournal

Wang Q, Zhou N, Lou X, Chen X.
PMID: 25243215
ScientificWorldJournal. 2014;2014:538520. doi: 10.1155/2014/538520. Epub 2014 Aug 27.

Unbalanced grid faults will lead to several drawbacks in the output power quality of photovoltaic generation (PV) converters, such as power fluctuation, current amplitude swell, and a large quantity of harmonics. The aim of this paper is to propose...

Designing a spoken dialogue interface to an intelligent cognitive assistant for people with dementia.

Health informatics journal

Wolters MK, Kelly F, Kilgour J.
PMID: 26276794
Health Informatics J. 2016 Dec;22(4):854-866. doi: 10.1177/1460458215593329. Epub 2015 Aug 14.

Intelligent cognitive assistants support people who need help performing everyday tasks by detecting when problems occur and providing tailored and context-sensitive assistance. Spoken dialogue interfaces allow users to interact with intelligent cognitive assistants while focusing on the task at...

Product development. And the winner is.

The Health service journal

Mooney H.
PMID: 22741365
Health Serv J. 2012 Apr 26;122(6303):Suppl 26-7.

No abstract available.

Working draft of the FDA GMP final rule (Part II).

Medical device technology

Donawa ME.
PMID: 10158131
Med Device Technol. 1995 Nov;6(9):9-12.

Part I of this two-part series provided information on the proposed design control provisions of the US Food and Drug Administration's (FDA) working draft of the final rule for new good manufacturing practice regulations for medical devices. The final...

Premarket approval--pro and contra.

Medical progress through technology

Hutten H.
PMID: 3747961
Med Prog Technol. 1986;11(2):55-6.

No abstract available.

[Usability and standards of medical devices].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation

Xin L.
PMID: 20391927
Zhongguo Yi Liao Qi Xie Za Zhi. 2010 Jan;34(1):47-9.

This article discusses about the definition of usability of medical devices and introduces the related international standards. It describes the significance of usability and the relationship with the risk analysis. Some advices are given to improve the usability and...

Contested Technologies and Design for Values: The Case of Shale Gas.

Science and engineering ethics

Dignum M, Correljé A, Cuppen E, Pesch U, Taebi B.
PMID: 26208574
Sci Eng Ethics. 2016 Aug;22(4):1171-1191. doi: 10.1007/s11948-015-9685-6. Epub 2015 Jul 25.

The introduction of new energy technologies may lead to public resistance and contestation. It is often argued that this phenomenon is caused by an inadequate inclusion of relevant public values in the design of technology. In this paper we...

BioInnovate Ireland--fostering entrepreneurial activity through medical device innovation training.

Annals of biomedical engineering

Bruzzi MS, Linehan JH.
PMID: 23494126
Ann Biomed Eng. 2013 Sep;41(9):1834-40. doi: 10.1007/s10439-013-0787-5. Epub 2013 Mar 14.

In the midst of a rich environment for medical device development and manufacturing, universities can play a critical role by developing relevant training programs to produce entrepreneurs who can be efficient and successful in creating early stage companies by...

Inpatient Outcomes of a Hands-free, Wireless Communication Device Implementation.

Computers, informatics, nursing : CIN

Carreon HF, Dutra D.
PMID: 32692031
Comput Inform Nurs. 2020 Jul;38(7):323-328. doi: 10.1097/CIN.0000000000000653.

No abstract available.

Showing 1 to 12 of 12 entries