Display options
Share it on

Korean J Pain. 2011 Mar;24(1):44-7. doi: 10.3344/kjp.2011.24.1.44. Epub 2011 Feb 25.

Epidural catheter malposition in a failed epidural anesthesia confirmed by computed tomography.

The Korean journal of pain

Se Jin Lee, Sang Ho Kim, Sun Young Park, Mun Gyu Kim, Bo Il Jung, Si Young Ok

Affiliations

  1. Department of Anesthesiology and Pain Medicine, College of Medicine, Soonchunhyang University, Seoul, Korea.

PMID: 21390178 PMCID: PMC3049976 DOI: 10.3344/kjp.2011.24.1.44

Abstract

We report a case of failed epidural anesthesia despite successful identification of the epidural space, loss of resistance technique, hanging drop method and drip infusion. This case evaluated the use of computed tomography to confirm epidural catheter position, which showed the catheter accidentally positioned at the T2 lamina. Because epidural anesthesia can even after successful procedure using standardized techniques such as loss of resistance, we recommend performing the procedure under fluoroscopic guidance to improve success rate and patient safety.

Keywords: catheter malposition; epidural anesthesia; epidural space

References

  1. Anesthesiology. 2003 Dec;99(6):1387-90 - PubMed
  2. Can J Anaesth. 1998 Jul;45(7):640-4 - PubMed
  3. Anesth Analg. 2008 May;106(5):1542-7, table of contents - PubMed
  4. Korean J Pain. 2010 Dec;23(4):247-53 - PubMed
  5. Reg Anesth Pain Med. 2007 Mar-Apr;32(2):102-6 - PubMed
  6. Br J Anaesth. 1979 Mar;51(3):253-8 - PubMed
  7. Anesth Analg. 2005 Aug;101(2):333-339 - PubMed
  8. Anesth Analg. 2003 Apr;96(4):1183-1187 - PubMed
  9. Saudi J Anaesth. 2010 May;4(2):117-8 - PubMed
  10. Acta Orthop Scand Suppl. 1960;46:1-100 - PubMed
  11. Anaesthesia. 1991 Oct;46(10):872-4 - PubMed
  12. Contrib Nephrol. 2010;164:39-45 - PubMed
  13. Masui. 1977 Aug;26(8):956-7 - PubMed
  14. Anaesthesia. 1998 Mar;53(3):238-43 - PubMed
  15. Acta Anaesthesiol Scand. 2008 Feb;52(2):256-61 - PubMed
  16. Anesthesiology. 1998 Aug;89(2):546-8 - PubMed

Publication Types