Display options
Share it on

Chem Cent J. 2012 Jan 26;6(1):9. doi: 10.1186/1752-153X-6-9.

Development and validation of a repharsed phase- HPLC method for simultaneous determination of rosiglitazone and glimepiride in combined dosage forms and human plasma.

Chemistry Central journal

Nahed M El-Enany, Amina A Abdelal, Fathalla F Belal, Yoshinori I Itoh, Mitsuhiro N Nakamura

Affiliations

  1. Department of Analytical Chemistry, Faculty of Pharmacy, University of Mansoura, Mansoura, 35516, Egypt. [email protected].

PMID: 22277722 PMCID: PMC3292994 DOI: 10.1186/1752-153X-6-9

Abstract

BACKGROUND: Rosiglitazone (ROZ) and glimepiride (GLM) are antidiabetic agents used in the treatment of type 2 diabetes mellitus. A survey of the literature reveals that only one spectrophotometric method has been reported for the simultaneous determination of ROS and GLM in pharmaceutical preparations. However the reported method suffers from the low sensitivity, for this reason, our target was to develop a simple sensitive HPLC method for the simultaneous determination of ROZ and GLM in their combined dosage forms and plasma.

RESULTS: A simple reversed phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous determination of Rosiglitazone (ROS) and Glimepiride (GLM) in combined dosage forms and human plasma. The separation was achieved using a 150 mm × 4.6 mm i.d., 5 μm particle size Symmetry® C18 column. Mobile phase containing a mixture of acetonitrile and 0.02 M phosphate buffer of pH 5 (60: 40, V/V) was pumped at a flow rate of 1 mL/min. UV detection was performed at 235 nm using nicardipine as an internal standard. The method was validated for accuracy, precision, specificity, linearity, and sensitivity. The developed and validated method was successfully used for quantitative analysis of Avandaryl™ tablets. The chromatographic analysis time was approximately 7 min per sample with complete resolution of ROS (tR = 3.7 min.), GLM (tR = 4.66 min.), and nicardipine (tR, 6.37 min). Validation studieswas performed according to ICH Guidelines revealed that the proposed method is specific, rapid, reliable and reproducible. The calibration plots were linear over the concentration ranges 0.10-25 μg/mL and 0.125-12.5 μg/mL with LOD of 0.04 μg/mL for both compounds and limits of quantification 0.13 and 0.11 μg/mL for ROS and GLM respectively.

CONCLUSION: The suggested method was successfully applied for the simultaneous analysis of the studied drugs in their co-formulated tablets and human plasma. The mean percentage recoveries in Avandaryl™ tablets were 100.88 ± 1.14 and 100.31 ± 1.93 for ROS and GLM respectively. Statistical comparison of the results with those of the reference method revealed good agreement and proved that there were no significant difference in the accuracy and precision between the two methods respectively. The interference likely to be introduced from some co-administered drugs such as glibenclamide, gliclazide, metformine, pioglitazone and nateglinide was investigated.

References

  1. Biomed Chromatogr. 2008 Jan;22(1):58-63 - PubMed
  2. J Chromatogr B Analyt Technol Biomed Life Sci. 2004 Apr 25;803(2):317-20 - PubMed
  3. J AOAC Int. 2009 Jan-Feb;92(1):119-24 - PubMed
  4. Pak J Pharm Sci. 2008 Oct;21(4):421-5 - PubMed
  5. Yao Xue Xue Bao. 2005 Aug;40(8):750-3 - PubMed
  6. J Chromatogr Sci. 2008 Jul;46(6):501-4 - PubMed
  7. Drugs. 1999 Jun;57(6):921-30; discussion 931-2 - PubMed
  8. Clin Ther. 2008 Dec;30(12):2272-9 - PubMed
  9. J Chromatogr B Analyt Technol Biomed Life Sci. 2009 Mar 1;877(7):645-8 - PubMed
  10. J Pharm Biomed Anal. 2001 Jan;24(3):507-15 - PubMed
  11. J AOAC Int. 2006 Sep-Oct;89(5):1296-9 - PubMed

Publication Types