Micrometre resolution of a charge integrating microstrip detector with single photon sensitivity.

Journal of synchrotron radiation

A Schubert, A Bergamaschi, C David, R Dinapoli, S Elbracht-Leong, S Gorelick, H Graafsma, B Henrich, I Johnson, M Lohmann, A Mozzanica, V Radicci, R Rassool, L Schädler, B Schmitt, X Shi, B Sobott

Affiliations

  1. School of Physics, The University of Melbourne, Melbourne, Victoria 3010, Australia. [email protected]

PMID: 22514170 PMCID: PMC3408957 DOI: 10.1107/S090904951200235X

Abstract

A synchrotron beam has been used to test the spatial resolution of a single-photon-resolving integrating readout-chip coupled to a 320 µm-thick silicon strip sensor with a dedicated readout system. Charge interpolation methods have yielded a spatial resolution of σ(x) ≃ 1.8 µm for a 20 µm-pitch strip.