Display options
Share it on

Sensors (Basel). 2013 Apr 02;13(4):4367-77. doi: 10.3390/s130404367.

A solid-contact ion selective electrode for copper(II) using a succinimide derivative as ionophore.

Sensors (Basel, Switzerland)

Mihaela Dana Tutulea-Anastasiu, Deivy Wilson, Manel del Valle, Cristina Mihaela Schreiner, Igor Cretescu

Affiliations

  1. Faculty of Chemical Engineering and Environmental Protection, Gheorghe Asachi Technical University, Iasi, Romania. [email protected]

PMID: 23549362 PMCID: PMC3673088 DOI: 10.3390/s130404367

Abstract

All-solid-state sensors with polyvinyl chloride (PVC)-based membranes using off-the-shelf N-hydroxysuccinimide (NHS) and succinimide (Succ) ionophores were prepared using DOP (dioctyl phthalate) and NPOE (ortho-nitrophenyloctyl ether) as plasticizers. Good responses were obtained when NHS was used. The potentiometric response of the proposed electrode is independent of pH over the range 2-6. The electrode shows a fast response time of 0.25 s. The electrode exhibits a Super-Nernstian response, with 37.5 mV/decade, with a potentiometric detection limit of 4.4 µM. The proposed sensor revealed good selectivity towards a group of transition metal ions.

References

  1. Environ Monit Assess. 2011 May;176(1-4):419-26 - PubMed
  2. Talanta. 2004 Oct 8;64(2):313-9 - PubMed
  3. J Solid State Electrochem. 2009 Jan 1;13(1):123-128 - PubMed
  4. Talanta. 2005 Oct 15;67(4):798-805 - PubMed
  5. Talanta. 2001 Dec 24;55(6):1047-54 - PubMed
  6. Talanta. 2006 Oct 15;70(3):656-60 - PubMed
  7. J AOAC Int. 2008 Nov-Dec;91(6):1478-82 - PubMed
  8. Environ Monit Assess. 2010 Sep;168(1-4):315-9 - PubMed
  9. Trends Analyt Chem. 2005 Mar;24(3):199-207 - PubMed

Publication Types