Display options
Share it on

J Int Oral Health. 2013 Oct;5(5):73-8. Epub 2013 Oct 26.

An in vitro Comparative Evaluation of Micro Tensile Bond Strength of Two metal bonding Resin Cements bonded to Cobalt Chromium alloy.

Journal of international oral health : JIOH

Smita Musani, Iqbal Musani, Ramandeep Dugal, Nitin Habbu, Pallavi Madanshetty, Danish Virani

Affiliations

  1. Department of Prosthodontics, M A Rangoonwala College of Dental Sciences & Research Centre, Pune, Maharashtra, India.

PMID: 24324308 PMCID: PMC3845288

Abstract

BACKGROUND: The purpose of this study was to evaluate and compare the micro tensile bond strength of two metal bonding resin cements to sandblasted cobalt chromium alloy.

MATERIALS & METHODS: Eight, Cobalt chromium alloy blocks of dimensions 10x5x5 mm were cast, finished and polished. One of the faces of each alloy block measuring 5x5mm was sandblasted with 50 μm grit alumina particles. The alloy blocks were then cleaned in an ultrasonic cleaner for 1 min and then air dried with an air stream. The Sandblasted surfaces of the two alloy blocks were bonded together with 2 different metal bonding resin systems (Panavia F Kuraray and DTK Kleber - Bredent). The samples were divided into 2 groups (n=4). Group 1- Two Co-Cr blocks were luted with Panavia cement. Group 2- Two Co-Cr blocks were luted with DTK Kleber-Bredent cement. The bonded samples were cut with a diamond saw to prepare Microtensile bars of approximately 1mm x 1mm x 6mm. Thirty bars from each group were randomly separated into 2 subgroups (n=15) and left for 3hrs (baseline) as per manufacturer's instructions while the other group was aged for 24hrs in 370C water, prior to loading to failure under tension at a cross head speed of 1mm/min. Failure modes were determined by means of stereomicroscopy (sm). Statistical analysis was performed through one way - ANOVA.

RESULTS: Significant variation in micro-tensile bond strength was observed between the two metal bonding resin systems.

CONCLUSION: DTK showed higher mean bond strength values than Panavia F cement both at baseline and after aging. How to cite this article: Musani S, Musani I, Dugal R, Habbu N, Madanshetty P, Virani D. An in vitro Comparative Evaluation of Micro Tensile Bond Strength of Two metal bonding Resin Cements bonded to Cobalt Chromium alloy. J Int Oral Health 2013;5(5):73-8.

Keywords: alloy; bonding; casting

References

  1. J Prosthet Dent. 2009 Feb;101(2):107-18 - PubMed
  2. Dent Mater. 1994 Jul;10(4):236-40 - PubMed
  3. Dent Mater. 1995 Mar;11(2):117-25 - PubMed
  4. Dent Mater. 2009 May;25(5):655-61 - PubMed
  5. Dent Mater. 1998 Jun;14(3):212-21 - PubMed
  6. J Dent Res. 1995 Sep;74(9):1591-6 - PubMed
  7. Eur J Oral Sci. 2005 Oct;113(5):429-35 - PubMed
  8. J Adhes Dent. 1999 Winter;1(4):299-309 - PubMed
  9. J Dent Res. 1997 Jun;76(6):1298-307 - PubMed

Publication Types