Abstract

BACKGROUND: Measurement of maximum inspiratory pressure is the most prevalent method used in clinical practice to assess the strength of the inspiratory muscles. Although there are many devices available for the assessment of inspiratory muscle strength, there is a dearth of literature describing the reliability of devices that can be used in clinical patient assessment. The capsule-sensing pressure gauge (CSPG-V) is a new tool that measures the strength of inspiratory muscles; it is easy to use, noninvasive, inexpensive and lightweight.

OBJECTIVE: To test the intra- and inter-rater reliability of a CSPG-V device in healthy adults.

METHODS: A cross-sectional study involving 80 adult subjects with a mean (± SD) age of 22±3 years was performed. Using simple randomization, 40 individuals (20 male, 20 female) were used for intrarater and 40 (20 male, 20 female) were used for inter-rater reliability testing of the CSPG-V device. The subjects performed three inspiratory efforts, which were sustained for at least 3 s; the best of the three readings was used for intra- and inter-rater comparison. The intra- and inter-rater reliability were calculated using intraclass correlation coefficients (ICCs).

RESULTS: The intrarater reliability ICC was 0.962 and the inter-rater reliability ICC was 0.922.

CONCLUSION: Results of the present study suggest that maximum inspiratory pressure measured using a CSPG-V device has excellent intraand inter-rater reliability, and can be used as a diagnostic and prognostic tool in patients with respiratory muscle impairment.

Keywords: Inter-rater reliability; Intrarater reliability; MIP; Maximal inspiratory pressure; Noninvasive device for maximum inspiratory pressure measurement

References

  1. Am J Respir Crit Care Med. 1998 Nov;158(5 Pt 1):1459-64 - PubMed
  2. Respir Care. 2011 Jun;56(6):776-82 - PubMed
  3. Am J Respir Crit Care Med. 2002 Aug 15;166(4):518-624 - PubMed
  4. Thorax. 1995 Jan;50(1):40-3 - PubMed
  5. Phys Ther. 1995 Nov;75(11):983-95 - PubMed
  6. Postgrad Med J. 1998 Apr;74(870):208-15 - PubMed
  7. Chest. 1993 Aug;104(2):448-53 - PubMed
  8. Respiration. 2001;68(1):22-7 - PubMed
  9. Thorax. 1984 Jul;39(7):535-8 - PubMed
  10. Thorax. 1995 Nov;50(11):1131-5 - PubMed
  11. Eur Respir J. 1998 Apr;11(4):901-5 - PubMed
  12. Braz J Med Biol Res. 1999 Jun;32(6):719-27 - PubMed

Publication Types