Iran J Pediatr. 2015 Feb;25(1):e184. doi: 10.5812/ijp.184. Epub 2015 Jan 19.

Agreement of Mixed Venous Carbon Dioxide Tension (PvCO2) and Transcutaneous Carbon Dioxide (PtCO2) Measurements in Ventilated Infants.

Iranian journal of pediatrics

Sinan Uslu, Ali Bulbul, Mesut Dursun, Umut Zubarioglu, Ebru Turkoglu, Omer Guran

Affiliations

  1. Division of Neonatology, Sisli Hamidiye Etfal Educational and Research Hospital, Istanbul, Turkey.

PMID: 26199686 PMCID: PMC4505968 DOI: 10.5812/ijp.184

Abstract

BACKGROUND: Noninvasive transcutaneous carbon dioxide monitoring has been shown to be accurate in infants and children, limited data are available to show the usefulness and limitations of partial transcutaneous carbon dioxide tension (PtCO2) value.

OBJECTIVES: The current study prospectively determines the effectiveness and accuracy of PtCO2 measurements in newborns.

MATERIALS AND METHODS: Venous blood gas sampling and monitoring of the PtCO2 level (TCM TOSCA, Radiometer) were done simultaneously. All measurements are performed on mechanically ventilated infants. Partial venous carbon dioxide tension (PvCO2) values divided into three groups according to hypocapnia (Group 1: < 4.68 kPa), normocapnia (Group 2: 4.68-7.33 kPa), hypercapnia (Group 3: > 7.33 kPa) and then PvCO2 and PtCO2 data within each group were compared separately.

RESULTS: A total of 168 measurements of each PvCO2 and PtCO2 data were compared in three separated groups simultaneously (13 in Group 1, 118 in Group 2, and 37 in Group 3). A bias of more than ± 0.7 kPa was considered unacceptable. PtCO2 was related to PvCO2 with acceptable results between the two measurements in hypocapnia (mean difference 0.20 ± 0.19 kPa) and normocapnia (0.002 ± 0.30 kPa) groups. On the other hand in hypercapnia group PtCO2 values were statistically significant (P < 0.001) and lower than PvCO2 data (mean difference 0.81 ± 1.19 kPa).

CONCLUSIONS: PtCO2 measurements have generally good agreement with PvCO2 in hypocapnic and normocapnic intubated infants but there are some limitations especially with high level of CO2 tension. Monitoring of PtCO2 is generally a useful non-invasive indicator of PvCO2 in hypocapnic and normocapnic infants.

Keywords: Blood Gas Analysis; Blood Gas Monitoring, Transcutaneous; Infant, Newborn

References

  1. Paediatr Anaesth. 2009 May;19(5):434-44 - PubMed
  2. BMC Pediatr. 2005 Aug 10;5:30 - PubMed
  3. Sensors (Basel). 2012;12 (8):10980-9 - PubMed
  4. Matern Child Health J. 2011 Dec;15 Suppl 1:S17-26 - PubMed
  5. Pediatr Pulmonol. 1992 Mar;12(3):153-7 - PubMed
  6. Adv Exp Med Biol. 1987;220:115-20 - PubMed
  7. Arch Dis Child Fetal Neonatal Ed. 2005 Nov;90(6):F523-6 - PubMed
  8. Eur J Pediatr. 1996 Dec;155(12):1043-6 - PubMed
  9. J Anesth. 2006;20(4):331-4 - PubMed
  10. Scand J Clin Lab Invest. 2011 Nov;71(7):548-52 - PubMed
  11. Anesth Analg. 2007 Dec;105(6 Suppl):S48-52 - PubMed
  12. World J Pediatr. 2008 Aug;4(3):192-6 - PubMed
  13. World J Pediatr. 2008 May;4(2):114-7 - PubMed
  14. J Perinatol. 2005 Jan;25(1):26-9 - PubMed
  15. Respir Care. 2012 Nov;57(11):1955-62 - PubMed
  16. Anesth Analg. 2008 Jul;107(1):125-9 - PubMed
  17. Chest. 2005 May;127(5):1744-8 - PubMed
  18. Crit Care Med. 1989 Jun;17(6):556-9 - PubMed
  19. Acta Paediatr. 2011 May;100(5):676-9 - PubMed
  20. Anesth Analg. 1997 Jul;85(1):55-8 - PubMed
  21. Crit Care Med. 1981 Oct;9(10 ):744-9 - PubMed
  22. Arch Dis Child. 2004 Feb;89(2):176-80 - PubMed

Publication Types