Display options
Share it on

Neth Heart J. 2015 Aug;23(9):438-46. doi: 10.1007/s12471-015-0729-y.

The symbiosis of contact force catheter use for hybrid ablation for atrial fibrillation.

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation

N Kumar, L Pison, P Lozekoot, R Choudhury, M La Meir, S Gelsomino, H Crijns, J Maessen

Affiliations

  1. Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht (CARIM), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands, [email protected].

PMID: 26153267 PMCID: PMC4547945 DOI: 10.1007/s12471-015-0729-y

Abstract

OBJECTIVE: Reconduction across an ablation line is a common reason for arrhythmia recurrence over time. The hybrid procedure combines epicardial ablation of the pulmonary vein (PV) and creation of a box lesion with endocardial touch-ups for any electrical gaps. A high contact force (CF) between the ablation tip and cardiac tissue may increase the risk of thrombus formation, catheter tip charring, steam pop formation, and even cardiac perforation. CF monitoring is a significant new parameter for titration of the CF for creating an adequate lesion.

METHODS: Thirty-eight consecutive patients underwent epicardial ablation using bipolar radiofrequency devices. After checking electrical bidirectional block of the ablation lines, an endocardial CF catheter was used for further ablation (if needed) to complete the isolation of PVs, box lesion, cavotricuspid isthmus (CTI), and complex fractionated atrial electrograms (CFAE).

RESULTS: Endocardial touch-up was needed for 2 PVs (1.3 %) and 10 (26.3 %) box lesions. It was also used for the CTI line in 7 (18.4 %) patients, atrial tachycardia in 3 (7.9 %) patients, and additional CFAE ablation in 17 (44.7 %) patients. All 5 patients with arrhythmia recurrence had a mean CF < 10 g (p = 0.03). Procedure duration was significantly shorter in the CF group (223 ± 57 vs. 256 ± 60 min, p = 0.03) compared with control group.

CONCLUSION: Use of CF catheters is safe, feasible, and complementary to a hybrid procedure setup for atrial fibrillation ablation. Its real-time monitoring may predict future arrhythmia recurrence, and decrease procedure time.

References

  1. Am J Cardiol. 1999 Nov 4;84(9A):139R-146R - PubMed
  2. N Engl J Med. 2002 Dec 5;347(23):1825-33 - PubMed
  3. Pacing Clin Electrophysiol. 2003 Mar;26(3):725-30 - PubMed
  4. Circulation. 2004 Oct 12;110(15):2090-6 - PubMed
  5. Pacing Clin Electrophysiol. 2005 Jan;28 Suppl 1:S106-9 - PubMed
  6. Circulation. 2005 Aug 2;112(5):627-35 - PubMed
  7. Circulation. 2006 Jan 3;113(1):11-9 - PubMed
  8. Pacing Clin Electrophysiol. 2006 Nov;29(11):1285-97 - PubMed
  9. J Cardiovasc Electrophysiol. 2008 Sep;19(9):897-903 - PubMed
  10. Chest. 2010 Feb;137(2):263-72 - PubMed
  11. Interact Cardiovasc Thorac Surg. 2010 Feb;10(2):306-11 - PubMed
  12. J Cardiovasc Electrophysiol. 2010 Jul;21(7):806-11 - PubMed
  13. J Cardiovasc Electrophysiol. 2011 Feb;22(2):137-41 - PubMed
  14. J Thorac Cardiovasc Surg. 2011 May;141(5):1093-7 - PubMed
  15. Curr Med Chem. 2011;18(24):3675-94 - PubMed
  16. Heart Rhythm. 2012 Jan;9(1):18-23 - PubMed
  17. Interact Cardiovasc Thorac Surg. 2012 Apr;14(4):445-50 - PubMed
  18. Ann Thorac Surg. 2012 Jun;93(6):2051-3 - PubMed
  19. Pacing Clin Electrophysiol. 2012 Nov;35(11):1312-8 - PubMed
  20. Circ Arrhythm Electrophysiol. 2012 Dec;5(6):1124-9 - PubMed
  21. J Am Coll Cardiol. 2013 Jul 9;62(2):103-107 - PubMed
  22. Circ Arrhythm Electrophysiol. 2013 Apr;6(2):327-33 - PubMed
  23. Heart Rhythm. 2013 Jul;10(7):962-9 - PubMed
  24. Circ Arrhythm Electrophysiol. 2013 Aug;6(4):746-53 - PubMed
  25. Neth Heart J. 2014 Jun;22(6):259-66 - PubMed
  26. Neth Heart J. 2014 Jan;22(1):30-6 - PubMed
  27. Heart Rhythm. 2014 Sep;11(9):1602 - PubMed
  28. Europace. 2014 Mar;16(3):335-40 - PubMed
  29. Circ Arrhythm Electrophysiol. 2014 Feb;7(1):63-8 - PubMed
  30. Int J Cardiol. 2014 May 1;173(2):229-35 - PubMed
  31. Clin Radiol. 2014 Aug;69(8):e367-8 - PubMed
  32. Interact Cardiovasc Thorac Surg. 2014 Oct;19(4):590-4 - PubMed
  33. J Interv Card Electrophysiol. 2015 Mar;42(2):91-9 - PubMed
  34. Anatol J Cardiol. 2015 Feb;15(2):123-4 - PubMed
  35. Res Cardiovasc Med. 2015 Feb 20;4(1):e25592 - PubMed
  36. J Atr Fibrillation. 2014 Jun 30;7(1):1060 - PubMed
  37. J Atr Fibrillation. 2013 Dec 31;6(4):988 - PubMed
  38. J Atr Fibrillation. 2013 Dec 31;6(4):1005 - PubMed
  39. JACC Clin Electrophysiol. 2015 Jun;1(3):220-221 - PubMed
  40. N Engl J Med. 1982 Apr 29;306(17):1018-22 - PubMed
  41. J Cardiovasc Electrophysiol. 1994 Dec;5(12):1045-52 - PubMed
  42. Circulation. 1995 Apr 15;91(8):2264-73 - PubMed
  43. Am J Cardiol. 1996 Jan 25;77(3):60A-75A - PubMed

Publication Types