Refractive index measurements of poly(methyl methacrylate) (PMMA) from 0.4-1.6 μm.

Applied optics

G Beadie, Michael Brindza, Richard A Flynn, A Rosenberg, James S Shirk

PMID: 26560600 DOI: 10.1364/AO.54.00F139

Abstract

Using a transmission-spectrum-based method, the refractive index of a 50 μm thick sample of poly(methyl methacrylate) (PMMA) was measured as a function of wavelength. To mitigate the effects of nonplane-parallel surfaces, the sample was measured at 16 different locations. The technique resulted in the measurement of index at several thousand independent wavelengths from 0.42 to 1.62 μm, with a relative RMS accuracy <0.5×10(-4) and absolute accuracy <2×10(-4).