Quant Imaging Med Surg. 2015 Oct;5(5):665-72. doi: 10.3978/j.issn.2223-4292.2015.10.01.

Daily patient setup error in prostate image guided radiation therapy with fiducial-based kilovoltage onboard imaging and conebeam computed tomography.

Quantitative imaging in medicine and surgery

Jason C Ye, Muhammad M Qureshi, Pauline Clancy, Lauren N Dise, John Willins, Ariel E Hirsch

Affiliations

  1. 1 Department of Radiation Oncology, Boston Medical Center and Boston University School of Medicine, Boston, MA 02118, USA ; 2 Department of Radiation Oncology, New York Presbyterian Hospital/Weill Cornell Medical Center, New York, NY 10065, USA.

PMID: 26682136 PMCID: PMC4671976 DOI: 10.3978/j.issn.2223-4292.2015.10.01

Abstract

BACKGROUND: This study examined the interfraction setup error in patients undergoing prostate radiotherapy using fiducial markers and on-board imaging.

METHODS: Patients (n=53) were aligned to the treatment isocenter by laser followed by orthogonal kilovoltage (kV) radiographs to visualize bony anatomy and implanted fiducial markers. The magnitude and direction of couch shifts for isocenter correction required was determined by image registration for bony anatomy and fiducial markers. Twice weekly, 25 of the 53 patients also underwent conebeam computed tomography (CBCT) to measure any residual error in patient positioning. Based on individual coordinate shifts from CBCT, a net three-dimensional (3D) residual shift magnitude vector R was calculated.

RESULTS: The average couch shifts were 0.26 and 0.40 cm in inferior direction and 0.25 and 0.33 cm in superior direction for alignments made with bony anatomy and fiducial markers, respectively (P<0.0001). There were no significant differences noted in the vertical or lateral planes between the two image registration methods. In subset of 25 patients, no residual shift from fiducial plain film set up was required with CBCT matching in 66.5%, 52.4% and 57.9% of fractions for longitudinal, vertical and lateral planes, respectively, with majority (79%) of patients having a net residual 3D shifts of <0.3 cm. The use of CBCT increased average treatment time by approximately 6 min compared to kV radiographs alone.

CONCLUSIONS: The residual setup errors following daily kV image guided localization, as determined by CBCT, were small, which demonstrates high accuracy of kV localization when fiducial markers are present.

Keywords: Conebeam computed tomography (CBCT); fiducial markers; image guided radiation therapy (IGRT); prostate cancer

References

  1. Radiat Oncol. 2010 Jun 10;5:52 - PubMed
  2. Int J Radiat Oncol Biol Phys. 2008 May 1;71(1):41-50 - PubMed
  3. Int J Radiat Oncol Biol Phys. 2001 Nov 15;51(4):880-914 - PubMed
  4. Int J Radiat Oncol Biol Phys. 2007 Oct 1;69(2):419-25 - PubMed
  5. Med Dosim. 2008 Winter;33(4):268-74 - PubMed
  6. Med Dosim. 2006 Summer;31(2):113-25 - PubMed
  7. Int J Radiat Oncol Biol Phys. 2008 Jan 1;70(1):272-9 - PubMed
  8. Int J Radiat Oncol Biol Phys. 2002 Aug 1;53(5):1337-49 - PubMed
  9. Int J Radiat Oncol Biol Phys. 2009 Feb 1;73(2):610-7 - PubMed
  10. Med Dosim. 2006 Summer;31(2):91-112 - PubMed
  11. Int J Radiat Oncol Biol Phys. 2007 Mar 1;67(3):942-53 - PubMed
  12. J Am Coll Radiol. 2012 Apr;9(4):233-8 - PubMed
  13. Int J Radiat Oncol Biol Phys. 2012 Mar 1;82(3):1208-16 - PubMed
  14. Radiat Oncol. 2012 Apr 02;7:56 - PubMed
  15. Int J Radiat Oncol Biol Phys. 2011 May 1;80(1):301-5 - PubMed
  16. Int J Radiat Oncol Biol Phys. 2006 Jun 1;65(2):378-87 - PubMed
  17. Acta Oncol. 2008;47(7):1271-8 - PubMed
  18. J Med Imaging Radiat Oncol. 2008 Oct;52(5):511-6 - PubMed
  19. JAMA. 2005 Sep 14;294(10):1233-9 - PubMed
  20. Strahlenther Onkol. 2009 Sep;185(9):588-95 - PubMed
  21. Am J Clin Oncol. 2011 Feb;34(1):16-21 - PubMed

Publication Types