Display options
Share it on

Eur J Trauma Emerg Surg. 2012 Dec;38(6):627-32. doi: 10.1007/s00068-012-0204-z. Epub 2012 Jul 14.

Minimally invasive plate osteosynthesis for distal radius fractures with a palmar locking plate.

European journal of trauma and emergency surgery : official publication of the European Trauma Society

N Takada, T Otsuka, K Yamada, H Suzuki, T Hasuo, A Kondo, M Fukuta

Affiliations

  1. Department of Orthopaedic Surgery, Nagoya City University, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi, 467-8602, Japan. [email protected].
  2. Department of Orthopaedic Surgery, Nagoya City University, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi, 467-8602, Japan.
  3. Department of Orthopaedic Surgery, Komaki City Hospital, 1-20 Jyobushi, Komaki, Aichi, 485-0852, Japan.

PMID: 26814548 DOI: 10.1007/s00068-012-0204-z

Abstract

PURPOSE: Since 2006, we have been performing minimally invasive plate osteosynthesis with a palmar locking plate and without division of the pronator quadratus muscle for repairing distal radial fractures. The purpose of this study was to present the surgical technique we have developed and to retrospectively evaluate the clinical outcomes.

METHODS: Twenty patients were treated with this technique between January and December 2007. The range of motion of the wrist and forearm, grip strength, and the quick disability of the arm, shoulder, and hand score were assessed at the latest follow-up examination, and postoperative complications were evaluated.

RESULTS: The average ranges of flexion and extension of the wrist were 55° and 60°, respectively. The average ranges of supination and pronation of the forearm were 88° and 86°, respectively. The average grip strength of the treated side was 71 % of that of the uninjured side. The average quick disability of the arm, shoulder, and hand score was 13.4 points. No patient had loss of fracture reduction, implant failure, deep infection, or tendon or nerve problems.

CONCLUSIONS: The small skin incisions of this technique are advantageous from the aesthetic viewpoint. Minimally invasive plate osteosynthesis is one of the options for the treatment of distal radial fractures.

Keywords: Distal radius; Fracture; Locking plate; MIPO; Osteosynthesis; Pronator quadrates

References

  1. Int Orthop. 2010 Feb;34(1):131-5 - PubMed
  2. Bull Hosp Jt Dis. 2004;62(1-2):18-23 - PubMed
  3. Int Orthop. 2007 Oct;31(5):657-64 - PubMed
  4. J Orthop Trauma. 2007 Jul;21(6):355-61 - PubMed
  5. J Bone Joint Surg Br. 1988 Nov;70(5):829-31 - PubMed
  6. Arch Orthop Trauma Surg. 2007 Sep;127(7):531-5 - PubMed
  7. J Orthop Trauma. 2006 Oct;20(9):602-7 - PubMed
  8. J Hand Surg Am. 1990 Jul;15(4):630-6 - PubMed
  9. Tech Hand Up Extrem Surg. 2008 Mar;12(1):2-6 - PubMed
  10. J Orthop Trauma. 2008 Mar;22(3):153-8 - PubMed
  11. Int Orthop. 2009 Aug;33(4):1119-26 - PubMed
  12. J Hand Surg Br. 1997 Oct;22(5):644-6 - PubMed
  13. J Orthop Trauma. 2010 Apr;24(4):212-6 - PubMed
  14. J Orthop Trauma. 2007 Oct;21(9):628-33 - PubMed
  15. Injury. 2006 Sep;37(9):877-87 - PubMed
  16. J Hand Surg Br. 1996 Dec;21(6):714-22 - PubMed
  17. J Hand Surg Br. 2005 May;30(2):220-5 - PubMed
  18. Injury. 2001 Dec;32 Suppl 3:SC14-23 - PubMed

Publication Types