Display options
Share it on

Am J Primatol. 1985;9(4):285-294. doi: 10.1002/ajp.1350090405.

Noninvasive measurement of blood pressure in African green monkeys (Cercopithecus aethiops).

American journal of primatology

N Kraft-Schreyer, E T Angelakos

Affiliations

  1. Department of Physiology and Biophysics, Hahnemann University, Philadelphia.

PMID: 31979507 DOI: 10.1002/ajp.1350090405

Abstract

Indirect measurements of arterial blood pressure were made in African green monkeys (Cercopithecus aethiops) employing a Doppler ultrasound stethoscope and standard cuff and an Infrasonde automatic blood pressure recorder. Measurements were obtained from anesthetized (10 mg/kg ketamine (HCI) and unanesthetized (1.5 mg/kg ketamine HCI) animals. Ketamine had no significant effect on blood pressure. Indirect measurements from the brachial artery were compared with direct femoral artery measurements and with each other. Systolic blood pressures measured by the Doppler (r = .948) and Infrasonde (r = .920) methods correlated closely with direct measurements but were significantly lower than systolic blood pressures measured by the direct method. Diastolic blood pressures measured by the Infrasonde method agreed closely with direct measurements (r = .947). Systolic blood pressures measured by the indirect methods correlated closely in both anesthetized (r = .973) and unanesthetized (r = .834) animals and were not significantly different. Mean blood pressures calculated from direct and Infrasonde measurements also correlated closely (r = .963), with direct measurements being 4 mmHg higher on the average. Mean blood pressures are less influenced by methodology and are more reproducible than other pressures. These noninvasive methods can be used to obtain simple and accurate measurements of blood pressure from anesthetized and unanesthetized monkeys and are of value in long-term studies in monkeys.

Copyright © 1985 Wiley‐Liss, Inc., A Wiley Company.

Keywords: African green monkeys; Cercopithecus aethiops; Doppler ultrasound; guenons; infrasonic blood pressure instrument; vervets

References

  1. Angelakos, E. T.: Evaluation of basal blood pressure in African green monkeys, pp 245–247 in The Use of Nonhuman Primates in Cardiovascular Diseases. S. S. Kalter, ed.: University of Texas Press, Austin, 1980. - PubMed
  2. Geddes, L. A.; Whistler, S. J.: The error in indirect blood pressurement with the incorrect size of cuff. American Heart Journal 96: 4–8, 1978. - PubMed
  3. Hodgkin, B. C.; Burkett, D. E.; Smith, E. B.: Non‐invasive measurement of systolic and diastolic blood pressure in swine. American Journal of Physiology 242 (11): H127–130, 1982. - PubMed
  4. Kazamias, T. M.; Gander, P. M.; Franklin, T. L.; Ross, J., Jr.: Blood pressure measurement with Doppler ultrasonic flowmeter. Journal of Applied Physiology: Respiratory, Environmental and Exercise Physiology 30: 585–588, 1971. - PubMed
  5. Kraft‐Schreyer, N.; Angelakos, E. T.: Selection of monkeys with elevated blood pressures. Federation Proceedings 39: 1186, 1980. - PubMed
  6. Kraft‐Schreyer, N.; Angelakos, E. T.: Blood pressures of offspring of hypertensive monkeys. Federation Proceedings 41: 1481, 1982. - PubMed
  7. McMahan, C. A.; Wigodsky, H. S.; Moore, G. T.: Direct and indirect blood pressure measurement in baboons. Journal of Applied Physiology: Respiratory, Environmental and Exercise Physiology 41: 806–809, 1976. - PubMed
  8. Moss, A. J.; Adams, F. H.: Auscultatory and intra‐arterial pressure: a comparison in children with special reference to cuff width. Journal of Pediatrics 66: 1094–1097, 1965. - PubMed
  9. Reichle, F. A.: Noninvasive blood pressure measurement in the rat by ultrasonic auscultation. Journal of Surgical Research 11: 539–544, 1971. - PubMed
  10. Smith, C. C.; Ansevin, A.: Blood pressure of the normal Rhesus monkey. Proceedings of the Society for Experimental Biology and Medicine 96: 428–432, 1957. - PubMed
  11. Van Bergen, F. H.; Weatherhead, S.; Treloar, A. E.; Dobkin, A. G.; Buckley, J. J.: Comparison of indirect and direct methods of measuring arterial blood pressure. Circulation 10: 481–490, 1954. - PubMed
  12. Van Den Berg, B. J.: Comparisons of blood pressure measurements by auscultation and Physiometrics Infrasonde recording techniques. Hypertension 2, (Suppl I): 8–17, 1980. - PubMed
  13. Voors, A. W.; Foster, T. A.; Frerichs, R. R.; Webber, L. S.; Berenson, G. S.: Studies of blood pressures in children, ages 5–14 years, in a total biracial community. The Bogalusa heart study. Circulation 54: 319–327, 1976. - PubMed
  14. West, J. B. ed.: Best and Taylor's Physiological Basis of Medical Practice. Baltimore, Williams and Wilkins, 1985. - PubMed

Publication Types

Grant support