Display options
Share it on

Anesth Pain Med (Seoul). 2020 Oct 30;15(4):434-440. doi: 10.17085/apm.20055.

Change of inspired oxygen concentration in low flow anesthesia.

Anesthesia and pain medicine

Jiwook Kim, Donghee Kang, Hochul Lee, Sungwon Ryu, Siejeong Ryu, Doosik Kim

Affiliations

  1. Department of Anesthesiology and Pain Medicine, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea.

PMID: 33329846 PMCID: PMC7724113 DOI: 10.17085/apm.20055

Abstract

BACKGROUND: There are several advantages of low flow anesthesia including safety, economics, and eco-friendliness. However, oxygen concentration of fresh gas flow and inspired gas are large different in low flow anesthesia. This is a hurdle to access to low flow anesthesia. In this study, we aimed to investigate the change in inhaled oxygen concentration in low flow anesthesia using oxygen and medical air.

METHODS: A total of 60 patients scheduled for elective surgery with an American Society of Anesthesiologist physical status I or II were enrolled and randomly allocated into two groups. Group H: Fresh gas flow rate (FGF) 4 L/min (FiO₂ 0.5). Group L: FGF 1 L/min (FiO₂ 0.5). FGF was applied 4 L/min in initial phase (10 min) after intubation. After initial phase FGF was adjusted according to groups. FGF continued at the end of surgery. Oxygen and inhalation anesthetic gas concentration were recorded for 180 min at 15 min interval.

RESULTS: The inspired oxygen concentration decreased by 5.5% during the first 15 min in the group L. Inspired oxygen decreased by 1.5% during next 15 min. Inspired oxygen decreased by 1.4% for 30 to 60 min. The inspired oxygen of group L is 35.4 ± 4.0% in 180 min. The group H had little difference in inspired oxygen concentration over time and decreased by 1.8% for 180 min.

CONCLUSIONS: The inspired oxygen concentration is maintained at 30% or more for 180 min in patients under 90 kg. Despite some technical difficulties, low flow anesthesia may be considered.

Copyright © the Korean Society of Anesthesiologists, 2020.

Keywords: Balanced anesthesia; General anesthesia; Inspired oxygen; Low flow

Conflict of interest statement

CONFLICTS OF INTEREST No potential conflict of interest relevant to this article was reported.

References

  1. J Clin Anesth. 1995 Feb;7(1):49-53 - PubMed
  2. J Pharmacokinet Biopharm. 1989 Feb;17(1):109-23 - PubMed
  3. Br J Anaesth. 1998 Sep;81(3):361-4 - PubMed
  4. Br J Anaesth. 1994 Sep;73(3):322-5 - PubMed
  5. Anesthesiology. 1974 Feb;40(2):196-8 - PubMed
  6. Anaesthesia. 2010 Apr;65(4):379-87 - PubMed
  7. Br J Anaesth. 1976 Mar;48(3):217-23 - PubMed
  8. J Clin Diagn Res. 2017 Jul;11(7):UC29-UC33 - PubMed
  9. Anaesthesia. 1998 Mar;53(3):264-72 - PubMed
  10. Ann Surg. 1952 Dec;136(6):978-81 - PubMed
  11. Masui. 1997 Oct;46(10):1321-8 - PubMed
  12. Anaesth Intensive Care. 2019 May;47(3):223-225 - PubMed
  13. Anaesth Intensive Care. 1994 Aug;22(4):396-408 - PubMed
  14. Br J Anaesth. 1984 Feb;56(2):165-9 - PubMed

Publication Types