Annu Int Conf IEEE Eng Med Biol Soc. 2021 Nov;2021:354-358. doi: 10.1109/EMBC46164.2021.9630454.

Can Heart Sound Denoising be Beneficial in Phonocardiogram Classification Tasksƒ.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference

Melkamu Hunegnaw Asmare, Frehiwot Woldehanna, Luc Janssens, Bart Vanrumste

PMID: 34891308 DOI: 10.1109/EMBC46164.2021.9630454

Abstract

The purpose of computer-aided diagnosis (CAD) systems is to improve the detection of diseases in a shorter time and with reduced subjectivity. A robust system frequently requires a noise-free input signal. For CADs which use heart sounds, this problem is critical as heart sounds are often low amplitude and affected by some unavoidable sources of noise such as movement artifacts and physiological sounds. Removing noises by using denoising algorithms can be beneficial in improving the diagnostics accuracy of CADs. In this study, four denoising algorithms were investigated. Each algorithm has been carefully adapted to fit the requirements of the phonocardiograph signal. The effect of the denoising algorithms was objectively compared based on the improvement it introduces in the classification performance of the heart sound dataset. According to the findings, using denoising methods directly before classification decreased the algorithm's classification performance because a murmur was also treated as noise and suppressed by the denoising process. However, when denoising using Wiener estimation-based spectral subtraction was used as a preprocessing step to improve the segmentation algorithm, it increased the system's classification performance with a sensitivity of 96.0%, a specificity of 74.0%, and an overall score of 85.0%. As a result, to improve performance, denoising can be added as a preprocessing step into heart sound classifiers that are based on heart sound segmentation.

Publication Types