Display options
Share it on

JMIR Form Res. 2021 Nov 17;5(11):e29128. doi: 10.2196/29128.

A Two-Minute Walking Test With a Smartphone App for Persons With Multiple Sclerosis: Validation Study.

JMIR formative research

Pim van Oirschot, Marco Heerings, Karine Wendrich, Bram den Teuling, Frank Dorssers, René van Ee, Marijn Bart Martens, Peter Joseph Jongen

Affiliations

  1. Orikami Digital Health Products, Nijmegen, Netherlands.
  2. Dutch National Multiple Sclerosis Foundation, Rotterdam, Netherlands.
  3. Radboud University Medical Center, Nijmegen, Netherlands.
  4. Faculty of Science, Institute for Science in Society, Radboud University, Nijmegen, Netherlands.
  5. Sint Maartenskliniek, Nijmegen, Netherlands.
  6. Drug Target ID, Nijmegen, Netherlands.
  7. NeuroDrug Research BV, Nijmegen, Netherlands.
  8. Department of Community & Occupational Medicine, University Medical Centre Groningen, Groningen, Netherlands.
  9. MS4 Research Institute, Nijmegen, Netherlands.

PMID: 34787581 PMCID: PMC8663688 DOI: 10.2196/29128

Abstract

BACKGROUND: Walking disturbances are a common dysfunction in persons with multiple sclerosis (MS). The 2-Minute Walking Test (2MWT) is widely used to quantify walking speed. We implemented a smartphone-based 2MWT (s2MWT) in MS sherpa, an app for persons with MS. When performing the s2MWT, users of the app are instructed to walk as fast as safely possible for 2 minutes in the open air, while the app records their movement and calculates the distance walked.

OBJECTIVE: The aim of this study is to investigate the concurrent validity and test-retest reliability of the MS sherpa s2MWT.

METHODS: We performed a validation study on 25 persons with relapsing-remitting MS and 79 healthy control (HC) participants. In the HC group, 21 participants were matched to the persons with MS based on age, gender, and education and these followed the same assessment schedule as the persons with MS (the HC-matched group), whereas 58 participants had a less intense assessment schedule to determine reference values (the HC-normative group). Intraclass correlation coefficients (ICCs) were determined between the distance measured by the s2MWT and the distance measured using distance markers on the pavement during these s2MWT assessments. ICCs were also determined for test-retest reliability and derived from 10 smartphone tests per study participant, with 3 days in between each test. We interviewed 7 study participants with MS regarding their experiences with the s2MWT.

RESULTS: In total, 755 s2MWTs were completed. The adherence rate for the persons with MS and the participants in the HC-matched group was 92.4% (425/460). The calculated distance walked on the s2MWT was, on average, 8.43 m or 5% (SD 18.9 m or 11%) higher than the distance measured using distance markers (n=43). An ICC of 0.817 was found for the concurrent validity of the s2MWT in the combined analysis of persons with MS and HC participants. Average ICCs of 9 test-retest reliability analyses of the s2MWT for persons with MS and the participants in the HC-matched group were 0.648 (SD 0.150) and 0.600 (SD 0.090), respectively, whereas the average ICC of 2 test-retest reliability analyses of the s2MWT for the participants in the HC-normative group was 0.700 (SD 0.029). The interviewed study participants found the s2MWT easy to perform, but they also expressed that the test results can be confronting and that a pressure to reach a certain distance can be experienced.

CONCLUSIONS: The high correlation between s2MWT distance and the conventional 2MWT distance indicates a good concurrent validity. Similarly, high correlations underpin a good test-retest reliability of the s2MWT. We conclude that the s2MWT can be used to measure the distance that the persons with MS walk in 2 minutes outdoors near their home, from which both clinical studies and clinical practice can benefit.

©Pim van Oirschot, Marco Heerings, Karine Wendrich, Bram den Teuling, Frank Dorssers, René van Ee, Marijn Bart Martens, Peter Joseph Jongen. Originally published in JMIR Formative Research (https://formative.jmir.org), 17.11.2021.

Keywords: 2-Minute Walking Test; mobile phone; mobility; multiple sclerosis; relapsing remitting

References

  1. Mult Scler. 2021 May 26;:13524585211018103 - PubMed
  2. Clin Neurol Neurosurg. 2015 Nov;138:20-4 - PubMed
  3. Arch Phys Med Rehabil. 2007 Mar;88(3):374-80 - PubMed
  4. PLoS One. 2015 Apr 16;10(4):e0123822 - PubMed
  5. JMIR Mhealth Uhealth. 2020 Oct 27;8(10):e22108 - PubMed
  6. Stroke. 2001 Mar;32(3):656-60 - PubMed
  7. Arch Phys Med Rehabil. 2001 Oct;82(10):1478-83 - PubMed
  8. Gait Posture. 2021 Feb;84:114-119 - PubMed
  9. J Arthroplasty. 2018 Jun;33(6):1737-1744 - PubMed
  10. Int J MS Care. 2017 Sep-Oct;19(5):247-252 - PubMed
  11. Sensors (Basel). 2020 Oct 19;20(20): - PubMed
  12. J Med Internet Res. 2015 Aug 19;17(8):e202 - PubMed
  13. Front Neurol. 2018 Jul 13;9:561 - PubMed
  14. Adv Clin Exp Med. 2020 Apr;29(4):469-473 - PubMed
  15. J Med Internet Res. 2019 Aug 30;21(8):e14863 - PubMed
  16. Int J Chron Obstruct Pulmon Dis. 2017 Oct 09;12:2849-2857 - PubMed
  17. Int J MS Care. 2019 Nov-Dec;21(6):282-291 - PubMed
  18. Mult Scler Relat Disord. 2018 May;22:108-114 - PubMed
  19. IEEE J Biomed Health Inform. 2021 Mar;25(3):838-849 - PubMed
  20. Mult Scler Relat Disord. 2021 Jun;51:102943 - PubMed
  21. Arch Phys Med Rehabil. 2004 Sep;85(9):1525-30 - PubMed
  22. Biomed Eng Online. 2014 Feb 06;13:10 - PubMed
  23. Nurs Stand. 2014 Nov 18;29(11):49-58 - PubMed
  24. Mult Scler. 2004 Feb;10(1):55-60 - PubMed
  25. J Aging Phys Act. 2019 Apr 29;27(4):843-847 - PubMed
  26. Neurorehabil Neural Repair. 2014 Sep;28(7):621-31 - PubMed
  27. JMIR Mhealth Uhealth. 2020 Oct 5;8(10):e18160 - PubMed
  28. Int J MS Care. 2011 Spring;13(1):4-14 - PubMed
  29. Eur J Neurol. 2020 Mar;27(3):429-436 - PubMed
  30. Neurology. 1983 Nov;33(11):1444-52 - PubMed
  31. Exp Gerontol. 2019 Jan;115:9-18 - PubMed
  32. J Nurs Scholarsh. 2017 Jul;49(4):371-378 - PubMed
  33. Int J MS Care. 2018 Jul-Aug;20(4):158-163 - PubMed
  34. Mult Scler. 2010 May;16(5):618-26 - PubMed
  35. BMJ. 1995 Mar 11;310(6980):633 - PubMed
  36. J Neurol Sci. 2014 Mar 15;338(1-2):183-7 - PubMed

Publication Types