Advanced Search
Display options
Filter resources
Text Availability
Article type
Publication date
Species
Language
Sex
Age
Showing 1 to 12 of 20 entries
Sorted by: Best Match Show Resources per page
[Research progresses on deformable model in medical image processing].

Hang tian yi xue yu yi xue gong cheng = Space medicine & medical engineering

Xiao M, Yan Y, Xia SR.
PMID: 15852557
Space Med Med Eng (Beijing). 2005 Feb;18(1):75-8.

In recent years, image processing technique based on deformable models has been widely used in the field of medical image processing and analysis. This survey demonstrates the principle of two kinds of basic deformable models, i.e. parametric deformable model...

High-definition television: why we have to pass the electronic Surgical Education and Self-Assessment Program (SESAP) test.

Surgical endoscopy

Berci G, Phillips E.
PMID: 17619928
Surg Endosc. 2007 Aug;21(8):1261-3. doi: 10.1007/s00464-007-9471-x.

No abstract available.

High frequency optoacoustic microscopy.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference

Bost W, Stracke F, Weiss EC, Narasimhan S, Kolios MC, Lemor R.
PMID: 19964880
Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:5883-6. doi: 10.1109/IEMBS.2009.5334452.

Photoacoustic imaging--also called optoacoustic imaging--is a new hybrid modality of high tissue contrast which is based on the varying optical properties of tissue. The acoustic signal generated by pulsed laser absorption reports tissue-specific information with high spatial resolution. To...

Editorial for the MEDIA special issue on MICCAI 2012.

Medical image analysis

Delingette H, Golland P, Mori K.
PMID: 23830202
Med Image Anal. 2013 Oct;17(7):711. doi: 10.1016/j.media.2013.06.004.

No abstract available.

The method of micro-displacement measurement to improve the space resolution of array detector.

Medical engineering & physics

Yin Z, Wu X, Tang Y, Huang H.
PMID: 9679234
Med Eng Phys. 1998 Mar;20(2):149-51. doi: 10.1016/s1350-4533(97)00044-1.

This paper introduces the method of micro-displacement measurement to improve the space resolution of limited size array detector. This method could also be applied in various research areas, especially in image measurement of nuclear detection.

Simulation of spatial and contrast distortions in keyhole imaging.

Magnetic resonance in medicine

Spraggins TA.
PMID: 8057804
Magn Reson Med. 1994 Mar;31(3):320-2. doi: 10.1002/mrm.1910310312.

Keyhole imaging is a scheme introduced to improve temporal resolution in dynamic contrast-enhanced MRI by a factor of four or more. A "full" acquisition before contrast administration is followed by truncated acquisitions sensitive primarily to changes in image contrast....

Transparent 0 pi pulses.

Magnetic resonance in medicine

Lee JN.
PMID: 8255204
Magn Reson Med. 1993 Oct;30(4):520-2. doi: 10.1002/mrm.1910300419.

No abstract available.

[Turbo GSE: a rapid T2-weighted hybrid sequence for MR tomography with instruments of high-gradient field strength].

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

Fellner F, Kiefer B, Trenkler J, Fellner C.
PMID: 7948985
Rofo. 1994 Oct;161(4):366-8. doi: 10.1055/s-2008-1032546.

No abstract available.

Post-contrast 3D T1-weighted TSE MR sequences (SPACE, CUBE, VISTA/BRAINVIEW, isoFSE, 3D MVOX): Technical aspects and clinical applications.

Journal of neuroradiology = Journal de neuroradiologie

Bapst B, Amegnizin JL, Vignaud A, Kauv P, Maraval A, Kalsoum E, Tuilier T, Benaissa A, Brugières P, Leclerc X, Hodel J.
PMID: 32017974
J Neuroradiol. 2020 Sep;47(5):358-368. doi: 10.1016/j.neurad.2020.01.085. Epub 2020 Feb 01.

Post-contrast three-dimensional T1-weighted imaging of the brain is widely used for a broad range of vascular, inflammatory or tumoral diseases. The variable flip angle 3D TSE sequence is now available from several manufacturers (CUBE, General Electric; SPACE, Siemens; VISTA/BRAINVIEW,...

Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy.

Magnetic resonance imaging clinics of North America

Settecase F, Martin AJ, Lillaney P, Losey A, Hetts SW.
PMID: 26499277
Magn Reson Imaging Clin N Am. 2015 Nov;23(4):591-605. doi: 10.1016/j.mric.2015.05.003. Epub 2015 Aug 12.

The use of MR guidance for endovascular intervention is appealing because of its lack of ionizing radiation, high-contrast visualization of vessel walls and adjacent soft tissues, multiplanar capabilities, and potential to incorporate functional information such as flow, fluid dynamics,...

'Enhanced' characterization of cystic-cavitary lesions using DCE-MRI.

Respirology (Carlton, Vic.)

Rosenow T.
PMID: 27099099
Respirology. 2016 May;21(4):576-7. doi: 10.1111/resp.12795.

No abstract available.

Understanding pulsed magnetization transfer.

Journal of magnetic resonance imaging : JMRI

Graham SJ, Henkelman RM.
PMID: 9307918
J Magn Reson Imaging. 1997 Sep-Oct;7(5):903-12. doi: 10.1002/jmri.1880070520.

Using a two-pool exchange model of magnetization transfer (MT), numeric simulations were developed to predict the time dependence of longitudinal magnetization in both semisolid and liquid pools for arbitrary pulsed radiofrequency (RF) irradiation. Whereas RF excitation of the liquid...

Showing 1 to 12 of 20 entries