Display options
Share it on

Hip Pelvis. 2016 Jun;28(2):76-81. doi: 10.5371/hp.2016.28.2.76. Epub 2016 Jun 30.

Results of Primary Total Hip Arthroplasty Using 36 mm Femoral Heads on 1st Generation Highly Cross Linked Polyethylene in Patients 50 Years and Less with Minimum Five Year Follow-up.

Hip & pelvis

Won-Kee Choi, Myung-Rae Cho, Hee-Soo Kim, Jun-Ho Nam, Seung-Bum Chae

Affiliations

  1. Department of Orthopaedic Surgery, Catholic University of Daegu College of Medicine, Daegu, Korea.

PMID: 27536648 PMCID: PMC4972889 DOI: 10.5371/hp.2016.28.2.76

Abstract

PURPOSE: We evaluated the clinical and radiographic midterm results of primary total hip arthroplasty (THA) using a 36 mm diameter femoral head on 1st generation highly cross-linked polyethylene (HXLPE) in patients 50 years and less with minimum five year follow-up.

MATERIALS AND METHODS: We retrospectively reviewed 31 patients (41 hips) aged 50 years and less underwent primary THA with a 36 mm diameter femoral head on HXLPE between 2004 and 2010. Clinical follow-ups included specific measurements like modified Harris hip scores (HHS) and Merle d'Aubigne and Postel score. For radiologic evaluations, together with position of acetabular cup at six weeks later of postoperation, we separately calculated the penentrations of femoral head into polyethylene liners during postoperation and one year later check-ups, and during one year later check-ups and final check-ups.

RESULTS: There were no major complications except for one case of dislocation. Average modified HHS at final follow-up was 88 (81-98), and Merle d'Aubigne and Postel scores were more than 15. Mean acetabular cup inclination and anteversion were 45.81°(36.33°-54.91°) and 13.26°(6.72°-27.71°), respectively. Average femoral head penetration of steady-state wear rate determined using radiographs taken at one-year postoperatively and at latest follow-up was 0.042±0.001 mm/year.

CONCLUSION: Based on minimum 5 years clinical results, we think 36 mm metal head coupling with HXLPE as the good alternate articulation surface when planning THA for patients aged 50 years and less.

Keywords: 36 mm femoral head; Highly cross-linked polyethylene; Total hip arthroplasty

References

  1. J Bone Joint Surg Am. 1992 Jul;74(6):849-63 - PubMed
  2. Hip Int. 2011 Sep-Oct;21(5):559-64 - PubMed
  3. J Bone Joint Surg Br. 1992 May;74(3):385-9 - PubMed
  4. J Bone Joint Surg Br. 1990 Jan;72 (1):53-9 - PubMed
  5. Acta Orthop. 2010 Oct;81(5):570-8 - PubMed
  6. Clin Orthop Relat Res. 2016 Feb;474(2):520-7 - PubMed
  7. Clin Orthop Relat Res. 2000 Oct;(379):22-8 - PubMed
  8. J Arthroplasty. 2012 Sep;27(8):1518-1525.e2 - PubMed
  9. J Bone Joint Surg Br. 1987 Jan;69(1):45-55 - PubMed
  10. J Bone Joint Surg Am. 2005 Mar;87(3):530-5 - PubMed
  11. Biomaterials. 2005 Mar;26(8):905-15 - PubMed
  12. J Arthroplasty. 2013 May;28(5):815-7 - PubMed
  13. Bone Joint J. 2016 Jan;98-B(1 Suppl A):14-7 - PubMed
  14. J Bone Joint Surg Am. 1993 May;75(5):740-51 - PubMed
  15. J Arthroplasty. 2011 Oct;26(7):1014-9 - PubMed
  16. Clin Orthop Relat Res. 2014 Feb;472(2):624-9 - PubMed
  17. Clin Orthop Relat Res. 2006 Jun;447:53-9 - PubMed
  18. J Arthroplasty. 2002 Aug;17(5):649-61 - PubMed
  19. Instr Course Lect. 2004;53:49-65 - PubMed
  20. J Orthop Res. 2006 Mar;24(3):422-7 - PubMed
  21. J Bone Joint Surg Am. 2009 Jun;91(6):1344-9 - PubMed
  22. J Arthroplasty. 2004 Apr;19(3):387-90 - PubMed
  23. J Arthroplasty. 2008 Oct;23(7 Suppl):39-43 - PubMed
  24. J Arthroplasty. 1998 Aug;13(5):530-4 - PubMed
  25. Int Orthop. 2010 Dec;34(8):1123-7 - PubMed
  26. J Bone Joint Surg Am. 2007 Oct;89(10):2212-7 - PubMed
  27. Clin Orthop Relat Res. 2016 Oct;474(10 ):2115-22 - PubMed

Publication Types