Advanced Search
Display options
Filter resources
Text Availability
Article type
Publication date
Species
Language
Sex
Age
Showing 1 to 12 of 268 entries
Sorted by: Best Match Show Resources per page
Dynamic granularity of imaging systems.

The Review of scientific instruments

Geissel M, Smith IC, Shores JE, Porter JL.
PMID: 26628138
Rev Sci Instrum. 2015 Nov;86(11):113701. doi: 10.1063/1.4934543.

Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution....

Pitfalls to avoid in the medical management of mass casualty incidents following terrorist bombings: the hospital perspective.

European journal of trauma and emergency surgery : official publication of the European Trauma Society

Ashkenazi I, Turégano-Fuentes F, Einav S, Kessel B, Alfici R, Olsha O.
PMID: 26816239
Eur J Trauma Emerg Surg. 2014 Aug;40(4):445-50. doi: 10.1007/s00068-014-0403-x. Epub 2014 May 01.

BACKGROUND: The unique patterns of injury following explosions together with the involvement of numerous physicians, most of whom are not experienced in trauma, may create problems in the medical management of mass casualty incidents.METHODS: Four hundred patient files admitted...

The weight of flash chromatography: A tool to predict its mass intensity from thin-layer chromatography.

Beilstein journal of organic chemistry

Pessel F, Augé J, Billault I, Scherrmann MC.
PMID: 28144302
Beilstein J Org Chem. 2016 Nov 08;12:2351-2357. doi: 10.3762/bjoc.12.228. eCollection 2016.

Purification by flash chromatography strongly impacts the greenness of a process. Unfortunately, due to the lack of the relevant literature data, very often this impact cannot be assessed thus preventing the comparison of the environmental factors affecting the syntheses....

Observation and Spectroscopy of New Proton-Unbound Isotopes ³⁰Ar and ²⁹Cl: An Interplay of Prompt Two-Proton and Sequential Decay.

Physical review letters

Mukha I, Grigorenko LV, Xu X, Acosta L, Casarejos E, Ciemny AA, Dominik W, Duénas-Díaz J, Dunin V, Espino JM, Estradé A, Farinon F, Fomichev A, Geissel H, Golubkova TA, Gorshkov A, Janas Z, Kamiński G, Kiselev O, Knöbel R, Krupko S, Kuich M, Litvinov YA, Marquinez-Durán G, Martel I, Mazzocchi C, Nociforo C, Ordúz AK, Pfützner M, Pietri S, Pomorski M, Prochazka A, Rymzhanova S, Sánchez-Benítez AM, Scheidenberger C, Sharov P, Simon H, Sitar B, Slepnev R, Stanoiu M, Strmen P, Szarka I, Takechi M, Tanaka YK, Weick H, Winkler M, Winfield JS, Zhukov MV.
PMID: 26613434
Phys Rev Lett. 2015 Nov 13;115(20):202501. doi: 10.1103/PhysRevLett.115.202501. Epub 2015 Nov 09.

Previously unknown isotopes (30)Ar and (29)Cl have been identified by measurement of the trajectories of their in-flight decay products (28)S+p+p and (28)S+p, respectively. The analysis of angular correlations of the fragments provided information on decay energies and the structure...

First Measurement of Several β-Delayed Neutron Emitting Isotopes Beyond N=126.

Physical review letters

Caballero-Folch R, Domingo-Pardo C, Agramunt J, Algora A, Ameil F, Arcones A, Ayyad Y, Benlliure J, Borzov IN, Bowry M, Calviño F, Cano-Ott D, Cortés G, Davinson T, Dillmann I, Estrade A, Evdokimov A, Faestermann T, Farinon F, Galaviz D, García AR, Geissel H, Gelletly W, Gernhäuser R, Gómez-Hornillos MB, Guerrero C, Heil M, Hinke C, Knöbel R, Kojouharov I, Kurcewicz J, Kurz N, Litvinov YA, Maier L, Marganiec J, Marketin T, Marta M, Martínez T, Martínez-Pinedo G, Montes F, Mukha I, Napoli DR, Nociforo C, Paradela C, Pietri S, Podolyák Z, Prochazka A, Rice S, Riego A, Rubio B, Schaffner H, Scheidenberger Ch, Smith K, Sokol E, Steiger K, Sun B, Taín JL, Takechi M, Testov D, Weick H, Wilson E, Winfield JS, Wood R, Woods P, Yeremin A.
PMID: 27419564
Phys Rev Lett. 2016 Jul 01;117(1):012501. doi: 10.1103/PhysRevLett.117.012501. Epub 2016 Jun 29.

The β-delayed neutron emission probabilities of neutron rich Hg and Tl nuclei have been measured together with β-decay half-lives for 20 isotopes of Au, Hg, Tl, Pb, and Bi in the mass region N≳126. These are the heaviest species...

Performance and grain yield stability of maize populations developed using marker-assisted recurrent selection and pedigree selection procedures.

Euphytica: Netherlands journal of plant breeding

Beyene Y, Semagn K, Mugo S, Prasanna BM, Tarekegne A, Gakunga J, Sehabiague P, Meisel B, Oikeh SO, Olsen M, Crossa J.
PMID: 27397932
Euphytica. 2016;208:285-297. doi: 10.1007/s10681-015-1590-1. Epub 2015 Nov 09.

A marker-assisted recurrent selection (MARS) program was undertaken in sub-Saharan Africa to improve grain yield under drought-stress in 10 biparental tropical maize populations. The objectives of the present study were to evaluate the performance of C

The proteolytic action of the snake venom enzymes arvin and reptilase on N-terminal chain-fragments of human fibrinogen.

FEBS letters

Hessel B, Blombäck M.
PMID: 11946152
FEBS Lett. 1971 Nov 01;18(2):318-320. doi: 10.1016/0014-5793(71)80476-3.

No abstract available.

Charge-exchange-induced two-electron satellite transitions from autoionizing levels in dense plasmas.

Physical review. E, Statistical, nonlinear, and soft matter physics

Rosmej FB, Griem HR, Elton RC, Jacobs VL, Cobble JA, Faenov AY, Pikuz TA, Geissel M, Hoffmann DH, Süss W, Uskov DB, Shevelko VP, Mancini RC.
PMID: 12513602
Phys Rev E Stat Nonlin Soft Matter Phys. 2002 Nov;66(5):056402. doi: 10.1103/PhysRevE.66.056402. Epub 2002 Nov 11.

Order-of-magnitude anomalously high intensities for two-electron (dielectronic) satellite transitions, originating from the He-like 2s(2) 1S0 and Li-like 1s2s(2) (2)S(1/2) autoionizing states of silicon, have been observed in dense laser-produced plasmas at different laboratories. Spatially resolved, high-resolution spectra and plasma...

Photoneutron cross sections for unstable neutron-rich oxygen isotopes.

Physical review letters

Leistenschneider A, Aumann T, Boretzky K, Cortina D, Cub J, Datta Pramanik U, Dostal W, Elze TW, Emling H, Geissel H, Grünschloss A, Hellstr M, Holzmann R, Ilievski S, Iwasa N, Kaspar M, Kleinböhl A, Kratz JV, Kulessa R, Leifels Y, Lubkiewicz E, Münzenberg G, Reiter P, Rejmund M, Scheidenberger C, Schlegel C, Simon H, Stroth J, Sümmerer K, Wajda E, Walús W, Wan S.
PMID: 11415271
Phys Rev Lett. 2001 Jun 11;86(24):5442-5. doi: 10.1103/PhysRevLett.86.5442.

The dipole response of stable and unstable neutron-rich oxygen nuclei of masses A = 17 to A = 22 has been investigated experimentally utilizing electromagnetic excitation in heavy-ion collisions at beam energies about 600 MeV/nucleon. A kinematically complete measurement...

Percutaneous coronary interventions in Europe 1992-2003.

EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology

Cook S, Togni M, Walpoth N, Maier W, Muehlberger V, Legrand V, Milicic D, Zambartas C, Zelizko M, Madsen JK, van Buuren F, Lòpez-Palop R, Peeba M, Koskenkorva J, Vanhanen H, Lablanche JM, Lazaris I, Géza F, Eyjolfsson K, Kearney P, Piscione F, Erglis A, Navickas R, Beissel J, Channam R, Koch K, Deleanu D, Melberg T, Witkowski A, Pereira H, Reho I, Fridrich V, Zorman D, Nilsson T, Oezmen F, Ludman P, Meier B.
PMID: 19755208
EuroIntervention. 2006 Feb;1(4):374-9.

AIMS: The purpose of this registry is to collect data on trends in interventional cardiology within Europe. Special interest focuses on relative increases and ratios in newer revascularization approaches and its distribution in different regions in Europe. We report...

Development and calibration of a Thomson parabola with microchannel plate for the detection of laser-accelerated MeV ions.

The Review of scientific instruments

Harres K, Schollmeier M, Brambrink E, Audebert P, Blazević A, Flippo K, Gautier DC, Geissel M, Hegelich BM, Nürnberg F, Schreiber J, Wahl H, Roth M.
PMID: 19044406
Rev Sci Instrum. 2008 Sep;79(9):093306. doi: 10.1063/1.2987687.

This article reports on the development and application of a Thomson parabola (TP) equipped with a (90x70) mm(2) microchannel-plate (MCP) for the analysis of laser-accelerated ions, produced by a high-energy, high-intensity laser system. The MCP allows an online measurement...

Schottky mass measurement of the 208Hg isotope: implication for the proton-neutron interaction strength around doubly magic 208Pb.

Physical review letters

Chen L, Litvinov YA, Plass WR, Beckert K, Beller P, Bosch F, Boutin D, Caceres L, Cakirli RB, Carroll JJ, Casten RF, Chakrawarthy RS, Cullen DM, Cullen IJ, Franzke B, Geissel H, Gerl J, Górska M, Jones GA, Kishada A, Knöbel R, Kozhuharov C, Litvinov SA, Liu Z, Mandal S, Montes F, Münzenberg G, Nolden F, Ohtsubo T, Patyk Z, Podolyák Z, Propri R, Rigby S, Saito N, Saito T, Scheidenberger C, Shindo M, Steck M, Ugorowski P, Walker PM, Williams S, Weick H, Winkler M, Wollersheim HJ, Yamaguchi T.
PMID: 19392270
Phys Rev Lett. 2009 Mar 27;102(12):122503. doi: 10.1103/PhysRevLett.102.122503. Epub 2009 Mar 27.

Time-resolved Schottky mass spectrometry has been applied to uranium projectile fragments which yielded the mass value for the 208Hg (Z=80, N=128) isotope. The mass excess value of ME=-13 265(31) keV has been obtained, which has been used to determine...

Showing 1 to 12 of 268 entries