JSLS. 2014 Oct-Dec;18(4). doi: 10.4293/JSLS.2014.00234.

Laparoscopic surgery skills evaluation: analysis based on accelerometers.

JSLS : Journal of the Society of Laparoendoscopic Surgeons

Alexis Sánchez, Omaira Rodríguez, Renata Sánchez, Gustavo Benítez, Romina Pena, Oriana Salamo, Valentina Baez

Affiliations

  1. Medicine Faculty, Central University of Venezuela, Caracas, Venezuela.
  2. Surgery Department III, University Hospital of Caracas, Caracas, Venezuela.

PMID: 25489218 PMCID: PMC4254482 DOI: 10.4293/JSLS.2014.00234

Abstract

BACKGROUND AND OBJECTIVE: Technical skills assessment is considered an important part of surgical training. Subjective assessment is not appropriate for training feedback, and there is now increased demand for objective assessment of surgical performance. Economy of movement has been proposed as an excellent alternative for this purpose. The investigators describe a readily available method to evaluate surgical skills through motion analysis using accelerometers in Apple's iPod Touch device.

METHODS: Two groups of individuals with different minimally invasive surgery skill levels (experts and novices) were evaluated. Each group was asked to perform a given task with an iPod Touch placed on the dominant-hand wrist. The Accelerometer Data Pro application makes it possible to obtain movement-related data detected by the accelerometers. Average acceleration and maximum acceleration for each axis (x, y, and z) were determined and compared.

RESULTS: The analysis of average acceleration and maximum acceleration showed statistically significant differences between groups on both the y (P = .04, P = .03) and z (P = .04, P = .04) axes. This demonstrates the ability to distinguish between experts and novices. The analysis of the x axis showed no significant differences between groups, which could be explained by the fact that the task involves few movements on this axis.

CONCLUSION: Accelerometer-based motion analysis is a useful tool to evaluate laparoscopic skill development of surgeons and should be used in training programs. Validation of this device in an in vivo setting is a research goal of the investigators' team.

Keywords: Accelerometers; Evaluation; Laparoscopic surgery; Training; iPod Touch

References

  1. Surg Endosc. 2013 May;27(5):1468-77 - PubMed
  2. Surg Endosc. 2013 Mar;27(3):1029-39 - PubMed
  3. JSLS. 2012 Jan-Mar;16(1):10-5 - PubMed
  4. Surg Endosc. 2011 Mar;25(3):771-5 - PubMed
  5. Surg Endosc. 2011 Feb;25(2):356-66 - PubMed
  6. JSLS. 2010 Apr-Jun;14(2):246-50 - PubMed
  7. Surg Endosc. 2009 Oct;23(10):2181-90 - PubMed
  8. Actas Urol Esp. 2009 Mar;33(3):284-9 - PubMed
  9. Curr Probl Surg. 2009 Apr;46(4):271-370 - PubMed
  10. World J Surg. 2008 Feb;32(2):156-60 - PubMed
  11. Minim Invasive Ther Allied Technol. 2007;16(6):328-40 - PubMed
  12. Surg Endosc. 2007 Mar;21(3):418-21 - PubMed
  13. World J Gastroenterol. 2006 May 28;12(20):3219-24 - PubMed
  14. Am J Surg. 2005 Jul;190(1):107-13 - PubMed
  15. Am J Surg. 1999 Jan;177(1):28-32 - PubMed
  16. Stud Health Technol Inform. 2002;85:412-8 - PubMed
  17. Surg Endosc. 2002 Apr;16(4):640-5 - PubMed
  18. J Am Coll Surg. 2001 Nov;193(5):533-7 - PubMed
  19. J Am Coll Surg. 2001 Nov;193(5):479-85 - PubMed
  20. JSLS. 2013 Jul-Sep;17(3):445-9 - PubMed

MeSH terms

Publication Types